Specifications and Reference Numbers
| Product detail | Specification or reference |
|---|---|
| Product type | DENSO HP3 fuel pump |
| Reference part numbers | 294000-2590 |
| Reference net weight | 4.6 kg |
| Reference carton size | 25 × 23 × 23 cm |
Applications
Matched engine applications. The assembly identified by 294000-2590 is checked against the engine actually fitted. Control-valve operation and any required learning procedure depend on the installed system.
DENSO HP3 294000-2590 control setup
|
Operating and Maintenance Notes: After installing a new fuel pump, replace both the engine oil filter and the diesel fuel filter. Clean the fuel tank and fuel lines; for common rail systems, clean the common rail as well. Related Components: When installing a fuel injection pump or injector, tighten pipe connections, component fasteners and flange mounting bolts to the specified torque to prevent loosening and damage to the pump or injector. |
![]() |
What to Send for a Fitment Check
For DENSO HP3 injection pump 294000-2590, send the original full marking, installed engine or parent assembly identification, and quantity. Include a close-up of the relevant mating interface if the reference is incomplete.
About BOSTEN
Product FAQ
Does replacing an HP3 SCV require a learning procedure?
Follow the specific engine and valve service instructions. Some systems require a diagnostic routine after the component is fitted.
Does low rail pressure prove DENSO HP3 high-pressure common rail pump is faulty?
Check low-pressure supply, inlet control, sensor feedback and injector leakage. Those parts can change rail pressure even when the pump is serviceable.
Can the inlet valve be replaced separately from this pump?
Confirm the valve's serviceability for the exact pump and the diagnosed fault. Match its own marking with the parent pump tag.
Should the fuel system be checked for air after pump replacement?
Follow the engine's priming and leak-check procedure. Inadequate supply or air in the feed circuit can affect startup and pressure build-up.
What should a replacement quote for 294000-2590 specify?
Specify the complete pump assembly, supply condition and any separately required mating pieces. Control-valve operation and any required learning procedure depend on the installed system.
Our Testing Equipment
BOSCH EPS815
BOSCH DCI700
Hartridge
AVM2, Toledo, Sabre CRI Expert, CRIPC, PGM20-12, PGM10-18…